Marca | Integra Metering AG (formerly Aquametro) |
Prodotto | 91009 VZO 50 FL 130/25 |
Codice interno | PRT4856227 |
Contattaci per avere un'offerta per il prodotto 91009 VZO 50 FL 130/25 oppure per qualsiasi prodotto della Integra Metering AG (formerly Aquametro) .
Vendiamo solo prodotti ORIGINALI E NUOVI.
La nostra azienda non è un distributore autorizzato. Tutti i diritti sono riservati ai produttori e ai loro partner ufficiali.
VSR 32 1 1 / 4'' OR Klinger Sil; Fittings DN 32 Fittings R 1 1/4 " Union nuts G 1 1/2 " without boundary (brass) with seals
VSR 40 1 1/2 '' OR Klinger Sil; Fittings DN 40 Fittings R 1 1/2 " Union nuts G 2 " without boundary (brass) with seals
81166 VSR 20 3/4" OR KLINGER SIL
alcune ghiandole
Anello pistone Durchflussm. DOMINO pistone rotante metri - corpo inox, flange DIN 2501 - acciaio inossidabile camera di misurazione - grafite pistone anello - guarnizioni in PTFE / Variseal
cassiere
DOMINO® ARD Construction Group - Reguliergetriebe - pulser per alte temperature NAMUR / DIN 19234 - rullo 6 cifre, girevole. - anello di bloccaggio con coperchio
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls water meter
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Ölzähler
VZO 15 ... 40 con filo, PN 16
Fuel-oil fuel meter
contatore dell'olio
M-Bus pulse collector
PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
94252 PMGF 32-RH1 5.0_150_1 1/4"
Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking
PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
counter
PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
CE test water meter R49 DN15-32