Marca | Integra Metering AG (formerly Aquametro) |
Prodotto | 93731 |
Codice interno | PRT4790263 |
Contattaci per avere un'offerta per il prodotto 93731 oppure per qualsiasi prodotto della Integra Metering AG (formerly Aquametro) .
Vendiamo solo prodotti ORIGINALI E NUOVI.
La nostra azienda non è un distributore autorizzato. Tutti i diritti sono riservati ai produttori e ai loro partner ufficiali.
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 10; Nominal diameter: DN 40; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Nominal flow: Qn = 6; Nominal diameter: DN 32; Reporting: 1 liter of 1impuls
Ölzähler
VZO 15 ... 40 con filo, PN 16
Fuel-oil fuel meter
contatore dell'olio
M-Bus pulse collector
PMG 32-RH1 6.0_260_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0,075 m³ / h Continuous flow qp: 6 m³ / h Maximum flow qs: 12 m³ / h Kvs-value: 12.7 m³ / h Pressure loss at qp: 0,22 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
94252 PMGF 32-RH1 5.0_150_1 1/4"
Size: DN 32 with thread 1 1/2 "(for screw 1 1/4") Nominal pressure: PN 16 bar length: 150 mm Mounting position: vertical falling temperature max .: 130 ° C Maximum flow qs: 6.3 m3 / h Nominal flow qp: 5 m3 / h minimum flow qi: 0.1 m3 / h pulse value: 1 l Smallest readable amount: 0.1 l registrable: 99,999 m3 measuring principle: multi-jet impeller, dry running With CE marking
PMGS 32-RH1 5.0_150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical ascending Riser counter Temperature: max. 130 ° C Nominal pressure: PN 16 Minimum flow qi: 0.1 m³ / h Continuous flow qp: 5 m³ / h Maximum flow qs: 6,3 m³ / h Kvs-value: 13.6 m³ / h Pressure loss at qp: 0,14 bar Pulse value: 1 liter / pulse Environmental class C according to EN 1434 no inlet: 0 x DN 32 no outlet flow: 0 x DN 32 Approval MI-004
counter
PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001
PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001
CE test water meter R49 DN15-32
CE test water meter R49 DN40-50
ART.NO. 80113/2008 AQUAPULS 1L
Electronic reading system IP68
Last crop per meter
ART.NO. 92042 VZO 15 RC 130/16-RV0,1
Contatore olio combustibile
ART.NO. 92048 VZO 20 RC 130/16-RV1
CONTOIL® oil meter VZO 15 RC 130/16-RV 0.1 Ring piston meter for mineral oil, with rotatable roller counter
P / N 92280 Aquametro Oil Meter
G/E F.O SUPPLY FLOW METER
mechanical counter tmax:60C DN 4mm Qmax 80 l/h Qn 50 l/h PN25bar Qmin 1 l/h 1,25ml/mp